Description
IEC 61850-3 and IEC 62439-3 full Gigabit managed redundancy box, with 3 10/100/1000BaseT(X) ports or 100/1000Base SFP ports, 1 10/100/1000BaseT(X) Ethernet console port, 1 isolated dual power input (88 to 300 VDC or 85 to 264 VAC), -40 to 85C operating temperature
Ethernet Interface
-
Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP+)
- 3
-
Console Port
- Ethernet console (10/100/1000Mbps RJ45)
-
Standards
- IEEE 802.3 for 10BaseT
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3z for 1000BaseSX/LX/LHX/ZX
- IEEE 802.3 for 10BaseT
Ethernet Software Features
-
Filter
- Static Multicast
-
Industrial Protocols
- Modbus TCP
-
Management
- Back Pressure Flow Control, BOOTP, DHCP Client, Fiber check, Flow control, HTTP, IPv4/IPv6, LLDP, Port Mirror, RARP, RMON, SMTP, SNMP Inform, SNMPv1/v2c/v3, Syslog, Telnet
-
Power Substation
- MMS
-
Redundancy Protocols
- HSR, PRP, RSTP grouping
-
Security
- HTTPS/SSL, TACACS+, RADIUS, SSH, Trust access control
-
Time Management
- NTP Server/Client, SNTP, IEEE 1588v2 PTP (hardware-based)
-
MIB
- IEC 62439-3 MIB
USB Interface
-
Storage Port
- USB Type A
Serial Interface
-
Console Port
- USB-serial console (Type B connector)
Input/Output Interface
-
Alarm Contact Channels
- Resistive load: 1 A @ 24 VDC
-
Digital Inputs
- +13 to +30 V for state 1
-30 to +3 V for state 0
Max. input current: 8 mA
- +13 to +30 V for state 1
Power Parameters
-
Input Voltage
- Redundant dual inputs
110/220 VAC/VDC (85 to 264 VAC, 88 to 300 VDC)
- Redundant dual inputs
-
Overload Current Protection
- Supported
-
Reverse Polarity Protection
- Supported
-
Input Current
- 0.260/0.170 A @ 110/220 VAC
0.150/0.080 A @ 110/220 VDC
- 0.260/0.170 A @ 110/220 VAC
-
Power Connector
- 1 removable 5-contact terminal block(s)
Physical Characteristics
-
Housing
- Aluminum
-
IP Rating
- IP40
-
Dimensions (without ears)
- 80 x 160 x 110 mm (3.15 x 6.30 x 4.33 in)
-
Weight
- 1210 g (2.69 lb)
-
Installation
- DIN-rail mounting
Environmental Limits
-
Operating Temperature
- -40 to 85°C (-40 to 185°F)
-
Storage Temperature (package included)
- -40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
- 5 to 95% (non-condensing)
Standards and Certifications
-
Safety
- UL 508
-
EMI
- EN 55032 Class A, CISPR 32, FCC Part 15B Class A
-
EMS
- IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 35 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
IEC 61000-4-11 DIPs
- IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
-
Power Substation
- IEC 61850-3, IEEE 1613
-
Railway
- EN 50121-4
MTBF
-
Time
- 566,844 hrs
-
Standards
- Telcordia (Bellcore) Standard TR/SR
Warranty
5 years