EN 50155 Layer 2 multi-Gigabit switch with 4 Gigabit Ethernet ports, 8 Gigabit Ethernet PoE+ ports, 2 10G Ethernet PoE+ ports, 2 10G Ethernet ports with bypass relay, 120 W PoE power budget, 24 to 110 VDC power input, IP40, -40 to 70°C operating temperature, conformal coating
Ethernet Interface
-
10GBaseT(X) Ports (M12 X-coded 8-pin female connector with bypass relay)
-
10/100/1000BaseT(X) Ports (M12 X-coded 8-pin female connector)
-
PoE Ports (10GBaseT(X), M12 X-coded 8-pin female connector)
- TN-G4516 non-BP models: 4
TN-G4516 BP models: 2
-
PoE Ports (100/1000BaseT(X), M12 X-coded 8-pin female connector)
-
Standards
- IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1X for authentication
IEEE 802.3 for 10BaseT
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3u for 100BaseT(X)
IEEE 802.3bz for 5GBaseT and 2.5GBaseT
IEEE 802.3an for 10GBaseT
IEEE 802.3ad for Port Trunk with LACP
IEEE 802.3af/at for PoE/PoE+ output
IEEE 802.3x for flow control
Ethernet Software Features
-
Broadcast Forwarding
-
Configuration Options
- Command Line Interface (CLI), Command Line Interface (CLI) through Serial/Telnet/SSH, Web Console (HTTP/HTTPS), Windows Utility
-
Filter
- 802.1Q
DHCP Filter
GMRP
GVRP
IGMP Snooping v1/v2/v3
IGMP Querier
Port-based VLAN
Static Multicast
-
Industrial Protocols
-
Management
- Account Management
Back Pressure Flow Control
DHCP Client (options 1/3/50/51/53/54/55/57/66/67)
DHCP option 82 (relay agent)
DHCP Server (options 1/3/12/15/42/50/55)
DNS Server
Flow control
HTTP
ICMP
IPv4/IPv6
Loop Protection
LLDP
Port-based DHCP Server
Port Mirror
QoS/CoS/ToS
RARP
RMON
SMTP
SNMP Inform
Syslog
Telnet
SNMP Trap
-
MIB
- Bridge MIB
Ethernet-like MIB
MIB-II
P-BRIDGE MIB
Q-BRIDGE MIB
RMON MIB Groups 1, 2, 3, 9
RSTP MIB
-
Redundancy Protocols
- LACP
MSTP
RSTP
STP
Static Port Trunk
Turbo Chain
Turbo Ring v2
Turbo Ring with DRC
-
Security
- Access control list
TACACS+
Broadcast storm protection
HTTPS/SSL
Local Account Accessibility
Port Lock
RADIUS
Rate Limit
SSH
Trust access control
-
Time Management
Switch Properties
-
IGMP Groups
-
Max. No. of VLANs
-
Priority Queues
-
VLAN ID Range
-
Jumbo Frame Size
LED Interface
-
LED Indicators
- PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL, Ethernet, PoE
Serial Interface
-
Console Port
- RS-232 (M12 B-coded 5-pin female connector)
Power Parameters
-
Input Voltage
-
No. of Power Inputs
-
Operating Voltage
-
Overload Current Protection
-
Reverse Polarity Protection
-
Total PoE Power Budget
-
Input Current
-
Power Connector
- M12 K-coded 5-pin male connector
Physical Characteristics
-
Housing
-
IP Rating
-
Dimensions
- 291.6 x 117.7 x 132.2 mm (11.48 x 4.63 x 5.20 in)
-
Weight
- TN-G4516 without bypass: 2,780g(6.13lb)
TN-G4516 with bypass: 2,790g(6.15lb)
-
Installation
-
Protection
- -CT model with PCB conformal coating
Environmental Limits
-
Operating Temperature
- -40 to 70°C (-40 to 158°F)
-
Storage Temperature (package included)
- -40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
- 5 to 95% (non-condensing)
-
Altitude
Standards and Certifications
-
EMC
-
EMS
- IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 6 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
-
Freefall
-
Radio Frequency
-
Railway
- EN 50121-4
EN 50155
IEC 60571
-
Railway Fire Protection
-
Safety
-
Shock
- IEC 60068-2-27, IEC 61373, EN 50155
-
Vibration
- IEC 60068-2-64, IEC 61373, EN 50155
MTBF
-
Time
- TN-G4516 without bypass: 436,136 hrs
TN-G4516 with bypass: 435,764 hrs
-
Standards