Description
2-port DF1 to EtherNet/IP gateway with 2 KV isolation, 0 to 55C operating temperature
Ethernet Interface
-
10/100BaseT(X) Ports (RJ45 connector)
- 2
Auto MDI/MDI-X connection
- 2
-
Magnetic Isolation Protection
- 1.5 kV (built-in)
Ethernet Software Features
-
Industrial Protocols
- Ethernet/IP (PCCC)
-
Configuration Options
- MGate Manager, Telnet Console
-
Management
- ARP, DHCP Client, SNMPv1, TCP/IP, Telnet, UDP
-
MIB
- RFC1213, RFC1317
Serial Interface
-
No. of Ports
- 2
-
Connector
- 2 x DB9 male
-
Serial Standards
- RS-232, RS-422
-
Baudrate
- 1200 bps to 921.6 kbps
-
Data Bits
- 8
-
Parity
- None, Even, Odd
-
Stop Bits
- 1, 2
-
Flow Control
- RTS/CTS, DTR/DSR (RS-232 only)
-
Isolation
- 2 kV (I models)
Serial Signals
-
RS-232
- TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
-
RS-422
- Tx+, Tx-, Rx+, Rx-, GND
Serial Software Features
-
Industrial Protocols
- DF1
DF1 (Transparent)
-
Mode
- Full duplex
-
Max. No. of Client Connections
- 8
Power Parameters
-
Input Voltage
- 12 to 48 VDC
-
Input Current
- 510 mA @ 12 VDC
Relays
-
Contact Current Rating
- Resistive load: 1 A @ 30 VDC
Physical Characteristics
-
Housing
- Plastic top cover, metal bottom plate
-
IP Rating
- IP30
-
Dimensions (with ears)
- 29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.90 in)
-
Dimensions (without ears)
- 29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in)
-
Weight
- 380 g (0.84 lb)
Environmental Limits
-
Operating Temperature
- 0 to 60°C (32 to 140°F)
-
Storage Temperature (package included)
- -40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
- 5 to 95% (non-condensing)
Standards and Certifications
-
Safety
- EN 60950-1, UL 508
-
EMC
- EN 55032/24
-
EMI
- CISPR 32, FCC Part 15B Class A
-
EMS
- IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
IEC 61000-4-11 DIPs
- IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
-
Hazardous Locations
- ATEX, Class I Division 2, IECEx
-
Freefall
- IEC 60068-2-32
-
Shock
- IEC 60068-2-27
-
Vibration
- IEC 60068-2-6, IEC 60068-2-64
MTBF
-
Time
- 1,204,573 hrs
-
Standards
- Telcordia SR332
Warranty
5 years