Universal I/O, 6 DIs, 6 relays, -40 to 85°C operating temperature
  Input/Output Interface
  -  
Buttons
    -  
Digital Input Channels
    -  
Isolation
    -  
Relay Channels
    
    Digital Inputs
  -  
Connector
   - Screw-fastened Euroblock terminal
  
     -  
Counter Frequency
    -  
Digital Filtering Time Interval
    -  
Dry Contact
   - On: short to GND
Off: open  
     -  
I/O Mode
    -  
Points per COM
    -  
Sensor Type
   - Dry contact
Wet Contact (NPN or PNP)  
     -  
Wet Contact (DI to COM)
   - On: 10 to 30 VDC
Off: 0 to 3 VDC  
     
    Relays
  -  
Breakdown Voltage
    -  
Connector
   - Screw-fastened Euroblock terminal
  
     -  
Contact Current Rating
   - Resistive load: 5 A @ 30 VDC, 250 VAC, 110 VAC
  
     -  
Contact Resistance
    -  
Electrical Endurance
   - 100,000 operations @ 5 A resistive load
  
     -  
Initial Insulation Resistance
   - 1,000 mega-ohms (min.) @ 500 VDC
  
     -  
Mechanical Endurance
    -  
Pulse Output Frequency
    -  
Type
   - Form A (N.O.) power relay
  
     -  
Note
   - Ambient humidity must be non-condensing and remain between 5 and 95%. The relays may malfunction when operating in high condensation environments below 0°C.
  
     
     Serial Interface
  -  
Baudrate
    -  
Connector
    -  
No. of Ports
    -  
Parity
    -  
Pull High/Low Resistor for RS-485
   - 1 kilo-ohm, 150 kilo-ohms
  
     -  
Serial Standards
    -  
Stop Bits
    -  
Surge
    -  
ESD
    -  
Data Bits
    -  
Flow Control
    
     Serial Software Features
  -  
Industrial Protocols
   - Modbus RTU Server (slave)
  
     
    Power Parameters
  -  
Power Connector
   - Screw-fastened Euroblock terminal
  
     -  
No. of Power Inputs
    -  
Input Voltage
    -  
Power Consumption
    
    Physical Characteristics
  -  
Housing
    -  
Dimensions
   - 27.8 x 124 x 84 mm (1.09 x 4.88 x 3.31 in)
  
     -  
Weight
    -  
Installation
   - DIN-rail mounting
Wall mounting  
     -  
Wiring
   - I/O cable, 16 to 26 AWG
Power cable, 12 to 24 AWG  
     
    Environmental Limits
  -  
Operating Temperature
   - -40 to 85°C (-40 to 185°F)
  
     -  
Storage Temperature (package included)
   - -40 to 85°C (-40 to 185°F)
  
     -  
Ambient Relative Humidity
   - 5 to 95% (non-condensing)
  
     -  
Altitude
    
    Standards and Certifications
  -  
EMC
    -  
EMI
   - CISPR 32, FCC Part 15B Class A
  
     -  
EMS
   - IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 0.5 kV
IEC 61000-4-5 Surge: Power: 2 kV
IEC 61000-4-6 CS: 3 V
IEC 61000-4-8 PFMF  
     -  
Safety
    -  
Shock
    -  
Vibration